Technical descriptions
Technical descriptions in PDF
Technical descriptions in PDF
Delivery and return information
Physical store contacts
Indoor unit SRK20ZS-WT SRK25ZS-W SRK35ZS-W SRK50ZS-W
Outdoor unit SRC20ZS-W SRC25ZS-W SRC35ZS-W SRC50ZS-W
Power supply 1Phase, 220 - 240V, 50Hz
Rated capacity (min. - max.) (Cooling) kW 2.0 (0.9∼2.9) 2.5 (0.9∼3.1) 3.5 (0.9∼4.0) 5.0 (1.3∼5.5)
Rated capacity (min. - max.) (Heating) kW 2.7 (0.9∼4.3) 3.2 (0.9∼4.5) 4.0 (0.9∼5.0) 5.8 (1.3∼6.6)
Energy consumption (Cooling) kW 0.44 0.62 0.89 1.35
Energy Consumption (Heating) kW 0.59 0.74 0.94 1.56
SEER / SCOP 8.50 / 4.60 8.50 / 4.70 8.40 / 4.70 7.00 / 4.60
Sound Pressure Indoor Unit Refrigeration (Hi/Me/Lo/Ulo) dB(A) 34 / 25 / 22 / 19 36 / 28 / 23 / 19 40 / 30 / 26 / 19 46 / 36 / 29 / 22
Heating (Hi/Me/Lo/Ulo) dB(A) 36 / 29 / 23 / 19 39 / 30 / 24 / 19 41 / 36 / 25 / 19 46 / 37 / 31 / 24
Outdoor unit Refrig. / Heat. dB(A) 45 / 45 46 / 46 50 / 48 51 / 52
Air flow Indoor unit Refrig. (Hi/Me/Lo/Ulo) m3/min 9.3 / 7.0 / 5.9 / 5.0 9.9 / 8.0 / 5.9 / 5.0 11.3 / 8.7 / 7.0 / 5.0 12.1 / 9.9 / 7.4 / 5.9
Heat. (Hi/Me/Lo/Ulo) m3/min 10.0 / 8.5 / 6.5 / 5.9 11.3 / 8.7 / 6.7 / 5.9 12.3 / 11.0 / 7.0 / 5.6 13.9 / 11.2 / 9.1 / 7.4
Outdoor unit Refrig. / heat. m3/min 27.4 / 23.6 27.4 / 23.6 31.5 / 27.8 32.8 / 32.8
Dimensions Indoor unit Height x width x depth mm 290 x 870 x 230
Outdoor unit mm 540 x 780(+62) x 290 595 x 780(+62) x 290
Weight Indoor / outdoor unit kg 9.5 / 31.0 9.5 / 34.5 10.0 / 36.0
Freon R32
Freon amount / addition from kg/m 0.62 / 15 0.78 / 15 1.05 / 15
Connection pipe diameter inches 1/4"; 3/8" 1/4"; 1/2"
Maximum piping length / height difference m 20 / 15 25 / 20
Operating outdoor temperature Cooling °C -15∼46
Operating outdoor temperature Heating -15∼24
Tags: Heat, pump, Mitsubishi, SRK25ZS-W, SRC25ZS-W