Technical descriptions
Technical descriptions in PDF
Technical descriptions in PDF
Delivery and return information
Physical store contacts
Indoor unit AWI-25HRDC1XD AWI-35HRDC1XC AWI-54HRDC1XC AWI-71HRDC1XC
Outdoor unit AWO-25HRDC1XD AWO-35HRDC1XC AWO-54HRDC1XC AWO-71HRDC1XC
Power supply 1Phase, 220 - 240V, 50Hz
Rated power (min. - max.) Cooling W 2650 (600–3100) 3500 (800–4100) 5100 (1300–5300) 7300 (1800–7400)
Heating W 2700 (800–3400) 3800 (1000–4200) 5200 (1300–5300) 7200 (1800–8000)
Energy consumption (min. – max.) Cooling W 810 (100–1600) 1180 (100–1600) 1067 (280–1800) 2200 (230–2760)
Heating W 720 (300–1600) 1100 (300–1600) 1400 (220–1500) 2200 (230–2530)
SEER / SCOP 6.5 / 4.0 6.1 / 4.0 6.7 / 4.0 6.53 / 4.09
Sound pressure Indoor unit SHi/Hi/Med/Low dB(A) 43/38/34/30/27 43/38/34/30/27 47/44/41/36/31 50/46/42/37/32
Outdoor unit dB(A) 52 54 57 63
Air flow Indoor unit SHi/Hi/Med/LowL m³/h 600/530/480/420 600/530/476/422 850/770/680/600 1300/1150/1010/870
Dimensions Indoor unit W×H×D mm 750×285×200 750×285×200 900×310×225 1082×330×233
Outdoor unit 649×456×244 705×530×280 715×537×280 900×700×350
Weight Indoor / outdoor unit kg 7.5 / 18.5 8.0 / 21 10.0 / 23 12.5 / 39
Freon R32
Freon amount / refill from kg/m 0.57 / 5 0.56 / 5 0.54 / 5 1.3 / 5
Freon refill amount g/m 15 20 25 30
Connection pipe diameter inches 1/4 - 3/8 1/4 - 3/8 1/4 - 1/2 1/4 - 5/8
Maximum pipe length / height difference m 20 / 10 20 / 10 25 / 15 50 / 25
Operating outdoor temperature Cooling °C -10 - +49
Heating °C -15 - +30
Tags: Heat, pump-air, conditioner, AlpicAir, AWI-35HRDC1XC, AWO-35HRDC1XC